Permissible Limit of Solids in water for Concrete - IS 456:2000 - Vk Study Civil

Permissible Limit of Solids in Concrete - IS 456:200 - Vk Study Civil

According to Indian Standard Code of Practice 456:2000 Fourth Revision

Permissible limits for solids is shown in table below - Potable water is considered satisfactory for mixing Concrete 


Table 1. Clause5.4 

Permissible Limit for Solids in Water for Concrete

SolidsTested as perPermissible limit,Max
Organic IS 3025
part 18
200 mg/l
InorganicIS 3025
part 18
3000 mg/l
Sulphates
as SO2
IS 3025
part 24
400 mg/l
Chlorides IS 3025
part 32
2000 mg/l
for Plain Concrete
ChloridesIS 3025
part 32
500 mg/l
for Reinforced concrete
Suspended
 Matter
IS 3025
part 17
2000 mg/l